Info:NASA Causeway Indian River: Difference between revisions
m (→Flow Factor) |
m (→Flow Factor) |
||
Line 46: | Line 46: | ||
NASA Causeway Flow Factor = 18.3% water constriction. | NASA Causeway Flow Factor = 18.3% water constriction. | ||
'''NASA Causeway impedes the Indian River's water flow for an estimated 12,940ft (2.45 miles) | '''NASA Causeway impedes the Indian River's water flow for an estimated 12,940ft (2.45 miles) or 81.7% of the lagoon's three mile width.''' | ||
[[File:Nasa_Causeway_Bridge_Length.jpg|800px|thumb|left|Bridge Length]] | [[File:Nasa_Causeway_Bridge_Length.jpg|800px|thumb|left|Bridge Length]] |
Revision as of 08:26, February 18, 2021
NASA Causeway Indian River | ||||
---|---|---|---|---|
Three mile long NASA Causeway connects SR405 in Titusville with Kennedy Space Center's NASA Parkway in Merritt Island, Florida. The causeway's 2,990ft bridge across the Indian River spans the Intracoastal Waterway (ICW) channel with a 142ft divided, four-lane, double-leaf bascule drawbridge. | ||||
Waterway: North Indian River | Road: SR405 | |||
City: Titusville | County: Brevard | |||
Type: Bascule Drawbridge | Builder:McCormick and Sons | |||
DOT: 703001 | L: 2993' | Built: 1964 | ||
Location: 28.5284,-80.76561
|
1964 NASA Parkway Causeway
Built in 1964, the NASA Causeway Bridge across the Indian River has
- reinforced concrete approaches
- aluminum handrails
- double-leaf bascule span
- and an estimated 12,940 feet of earthen berm causeway.
NASA Causeway's concrete bridge approaches are 1,460 x 28 feet long and the draw span is 142.75 x 28 feet.
The drawbridge provides an estimated 105ft of clearance to vessels in the ICW Channel when the span is opened.
The bridge has a three-story concrete control house that is 14.33 x 12.75 feet. The control house is capped by a metal and glass control room with a flat roof and walls that flare out from bottom to top.
Flow Factor
Our "Flow Factor" variable is a highly unscientific estimate of water flow constriction using Google Map Measurements.
Bridge Length / Lagoon Width = Flow Factor
2,900ft Bridge Length / 15,840ft Lagoon Width = 18.3%
NASA Causeway Flow Factor = 18.3% water constriction.
NASA Causeway impedes the Indian River's water flow for an estimated 12,940ft (2.45 miles) or 81.7% of the lagoon's three mile width.
National Bridge Inventory Data
NASA Parkway Causeway spans the Indian River Intracoastal Waterway channel with two double-leaf bascule draw span bridges, NBI #703001 & 703002.
Number | Road | Structure | Location | Water | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
703001 | SR405 | Main Span Westbound | Titusville | Indian River | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Number | Road | Structure | Location | Water | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
703002 | SR405 | Main Span Eastbound | Titusville | Indian River | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|