Info:Canaveral Locks Bridge: Difference between revisions

From Indian River Lagoon Project
mNo edit summary
mNo edit summary
 
Line 5: Line 5:
|City=Cape Canaveral
|City=Cape Canaveral
|County=Brevard
|County=Brevard
|Coordinates=28.40926,-80.63248
|Coordinates=28.40926, -80.63248
|Type=Bascule Triple Draw Span
|Type=Bascule Triple Draw Span
|Length=313.7
|Length=313.7
Line 14: Line 14:
|Article=Canaveral Locks Bridge
|Article=Canaveral Locks Bridge
|Image=image-canaveral-locks-bridge.jpg
|Image=image-canaveral-locks-bridge.jpg
|Link1=http://bridgehunter.com/fl/brevard/700117 Bridge Hunter
|Link1=https://www.google.com/maps/@28.4085784,-80.6319793,3a,75y,340.77h,87.69t/data=!3m6!1e1!3m4!1sqJPbIhJ2wFtHxqIYjtIU3g!2e0!7i16384!8i8192 Street View
|Link2=http://bridgereports.com/1084289 Bridge Reports
|Poster=Admin
|Poster=Admin
|Posted=20191203092947
|Posted=20191203092947
}}
}}
{{Bridge_Data_Query|where=Number_008|like=700117 }}
{{Bridge_Data_Query|where=Number_008|like=700117 }}

Latest revision as of 22:45, February 19, 2021


Canaveral Locks Bridge

Canaveral Locks Bridge
Located in Port Canaveral, Canaveral Locks Bridge is a set of three double leaf lift span drawbridges spanning State Road 401 from Kennedy Space Center across the Canaveral Barge Canal into Cape Canaveral. Article
Waterway: Banana River Road: SR401
City: Cape Canaveral County: Brevard
Type: Bascule Triple Draw Span
DOT: 700117 L: 313.7' H: 23' Built: 1972
Location: 28.40926, -80.63248

Web Links

Street View


National Bridge Data
Number 700117
Route 00401
Place Cape Canaveral
County Brevard
Features Service Rd & Canal
Facility SR-401 NB
Location SR-401 NB - Barge Canal
Latitude 28243318
Longitude 80375518
Service On Roadway Highway - Pedestrian
Service Under Roadway Highway - Waterway
Owner FDOT
Built 1972
Rebuilt 2010
Lanes 3
Lane Direction 1 way
Direction
Traffic 5900
Traffic Year 2017
Future Traffic 10236
Future Traffic Year 2039
Length 96m
Width 14m
Clearance
Kind Steel
Type Movable - Bascule
Deck Type Open Grating
Critical
Inspection Date (mm-yy) 09-16
Deck Satisfactory
Superstructure Fair
Substructure Satisfactory
Channel Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift.
Culvert N/A
Scour Bridge foundations determined to be stable for assessed or calculated scour condition. Scour is determined to be within the limits of footing or piles (Example B) by assessment (i.e.,bridge foundations are on rock formations that have been determined to resist scour within the service life of the bridge), by calculations or by installation of properly designed countermeasures