Info:NASA Causeway Indian River: Difference between revisions
mNo edit summary |
|||
Line 31: | Line 31: | ||
NASA Causeway's concrete bridge approaches are 1,460 x 28 feet long and the steel draw spans are 142.75 x 28 feet. | NASA Causeway's concrete bridge approaches are 1,460 x 28 feet long and the steel draw spans are 142.75 x 28 feet. | ||
When the | When the double-leaf span is open, the drawbridge provides an estimated 105ft of clearance to vessels in the Intracoastal Waterway channel. | ||
The bridge has a three-story concrete control house that is 14.33 x 12.75 feet. The control house is capped by a metal and glass control room with a flat roof and walls that flare out from bottom to top. | The bridge has a three-story concrete control house that is 14.33 x 12.75 feet. The control house is capped by a metal and glass control room with a flat roof and walls that flare out from bottom to top. |
Revision as of 05:55, February 23, 2021
NASA Causeway Indian River | ||||
---|---|---|---|---|
Three mile long NASA Causeway connects SR405 in Titusville with Kennedy Space Center's NASA Parkway in Merritt Island, Florida. The causeway's 2,990ft bridge across the Indian River spans the Intracoastal Waterway (ICW) channel with a 142ft divided, four-lane, double-leaf bascule drawbridge. | ||||
Waterway: North Indian River | Road: SR405 | |||
City: Titusville | County: Brevard | |||
Type: Bascule Drawbridge | Builder:McCormick and Sons | |||
DOT: 703001 | L: 2993' | Built: 1964 | ||
Location: 28.5284,-80.76561
|
1964 NASA Parkway Causeway
Built in 1964, the NASA Causeway Bridge across the Indian River has
- reinforced concrete approaches
- aluminum handrails
- double-leaf bascule span
- and an estimated 12,940 feet of earthen berm causeway.
NASA Causeway's concrete bridge approaches are 1,460 x 28 feet long and the steel draw spans are 142.75 x 28 feet.
When the double-leaf span is open, the drawbridge provides an estimated 105ft of clearance to vessels in the Intracoastal Waterway channel.
The bridge has a three-story concrete control house that is 14.33 x 12.75 feet. The control house is capped by a metal and glass control room with a flat roof and walls that flare out from bottom to top.
Flow Factor
Our "Flow Factor" variable is an unscientific estimate of water flow constriction using Google Map Measurements.
Bridge Length / Lagoon Width = Flow Factor
2,900ft Bridge Length / 15,840ft Lagoon Width = 18.3% Flow Factor
18.3% of the lagoon's width is spanned by the bridge and not impeded by the earthen berm causeway.
NASA Causeway impedes the Indian River's water flow for an estimated 12,940ft (2.45 miles) or 81.7% of the lagoon's three mile width.
National Bridge Inventory Data
NASA Parkway Causeway (SR405) spans the Indian River with two draw span bridges, NBI #703001 & 703002.
Number | Road | Structure | Location | Water | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
703001 | SR405 | Main Span Westbound | Titusville | Indian River | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Number | Road | Structure | Location | Water | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
703002 | SR405 | Main Span Eastbound | Titusville | Indian River | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|