Info:Eau Gallie Causeway

From Indian River Lagoon Project


Eau Gallie Causeway

Eau Gallie Causeway
The Eau Gallie causeway carries Eau Gallie Blvd. (Sr518) across the North Indian River lagoon in Melbourne, Florida.
Waterway: North Indian River Road: SR518
City: Melbourne County: Brevard
Type: High Span
DOT: 700184 L: 2901' Built: 1988
Location: 28.13259, -80.61798


Eau Gallie Causeway 2008

Eau Gallie Causeway (SR518) contains two bridges; a 2,901ft main span and a 702ft relief bridge:

Number Water Structure Road
700184 Indian River Main Span SR518
National Bridge Data
Number 700184
Route 00518
Place Melbourne
County Brevard
Features Indian River ICW
Facility SR-518
Location SR-518 over Indian River
Latitude 28075792
Longitude 80370269
Service On Roadway Highway - Pedestrian
Service Under Roadway Waterway
Owner FDOT
Built 1988
Rebuilt
Lanes 4
Lane Direction 2 way
Direction
Traffic 35500
Traffic Year 2016
Future Traffic 61592
Future Traffic Year 2038
Length 884m
Width 28m
Clearance
Kind Prestressed concrete continuous
Type Stringer/Multi-beam/Girder
Deck Type Concrete Cast-in-Place
Critical
Inspection Date (mm-yy) 06-16
Deck Satisfactory
Superstructure Good
Substructure Satisfactory
Channel Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly.
Culvert N/A
Scour Bridge foundations determined to be stable for assessed or calculated scour condition. Scour is determined to be within the limits of footing or piles by assessment, by calculations or by installation of properly designed countermeasures
Number Water Location Road
700183 Indian River East Relief SR518
National Bridge Data
Number 700183
Route 00518
Place Indian Harbour Beach
County Brevard
Features Indian River Relief
Facility SR-518
Location SR-518 - Indian River Rel
Latitude 28081497
Longitude 80360766
Service On Roadway Highway - Pedestrian
Service Under Roadway Waterway
Owner FDOT
Built 1988
Rebuilt
Lanes 4
Lane Direction 2 way
Direction
Traffic 35500
Traffic Year 2016
Future Traffic 61592
Future Traffic Year 2038
Length 214m
Width 30m
Clearance
Kind Concrete continuous
Type Slab
Deck Type Concrete Cast-in-Place
Critical
Inspection Date (mm-yy) 04-16
Deck Satisfactory
Superstructure Satisfactory
Substructure Good
Channel Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift.
Culvert N/A
Scour Bridge foundations determined to be stable for assessed or calculated scour condition. Scour is determined to be within the limits of footing or piles (Example B) by assessment (i.e.,bridge foundations are on rock formations that have been determined to resist scour within the service life of the bridge), by calculations or by installation of properly designed countermeasures