Drilldown: bridge data
From Indian River Lagoon Project
Choose a table:
- Event (169)
- News Link (111)
- Organization (18)
- Waterbody (27)
- bridge (13)
- bridge data (1468)
- definition (254)
- fips (487)
- repository (98)
- timeline (19)
- weblink (123)
Use the filters below to narrow your results.
'DRAINAGE DITCH ' (1) ·
'LATERAL CANAL #38 ' (1) ·
'Milner's Canal ' (1) ·
'Outfall ' (1) ·
'Outfall Ditch ' (1) ·
'Rockledge Canal ' (1) ·
'Santiago Canal ' (1) ·
'SR 710 and CSX RR ' (1) ·
'SR 802 LAKE WORTH RD ' (1) ·
'SR 808 GLADES RD ' (1) ·
'SR-514 ' (1) ·
'Tyson Creek ' (1) ·
'Wishbone Canal ' (1) ·
Brushy Canal (1) ·
Fiske Canal (1) ·
Palm Canal (1)
700046 (1) ·
700055 (1) ·
700094 (1) ·
700097 (1) ·
700098 (1) ·
700099 (1) ·
700100 (1) ·
700163 (1) ·
700164 (1) ·
700177 (1) ·
700202 (1) ·
700951 (1) ·
790113 (1) ·
890123 (1) ·
890144 (1) ·
930172 (1) ·
930173 (1) ·
930215 (1) ·
930416 (1) ·
931001 (1)
'0.4 Mi S of Grant Rd. ' (1) ·
'0.75 mile South of SR 708' (1) ·
'1.15 Mi S of SR-520 ' (1) ·
'1.2 Mi N L.Washington Rd.' (1) ·
'1.2 Mi S of Grant Rd ' (1) ·
'1.5 Mi S of Grant Rd. ' (1) ·
'1.5 Miles North of SR-528' (1) ·
'2 MILES N OF CR-708 ' (1) ·
'2.0 MI SOUTH OF SR-806 ' (1) ·
'2.0 MILES N OF SR 812 ' (1) ·
'2.2 Mi. S of Grant Rd. ' (1) ·
'2.4Mi N of Ind. River Co.' (1) ·
'2.5MI N OF INDIANTOWN RD ' (1) ·
'2.9 Mi. N of US 92 ' (1) ·
'I-95 - SR-514 ' (1) ·
'SR-91 FL TPK OVER SR-808 ' (1) ·
1.2 Mi S of Wickham R. (1) ·
1.5 MI S of Wickham Rd (1) ·
I-95 at Fiske Blvd. (1)
Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. (1) ·
Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and brush restrict the channel. (1) ·
Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. (1) ·
Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. (1) ·
N/A (1)
Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. (1) ·
Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting (1) ·
N/A (1) ·
Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. (1)
Bridge foundations determined to be stable for assessed or calculated scour condition. Scour is determined to be within the limits of footing or piles (Example B) by assessment (i.e.,bridge foundations are on rock formations that have been determined to resist scour within the service life of the bridge), by calculations or by installation of properly designed countermeasures (1) ·
Bridge foundations determined to be stable for the assessed or calculated scour condition. Scour is determined to be above top of footing (Example A) by assessment (i.e., bridge foundations are on rock formations that have been determined to resist scour within the service life of the bridge4), by calculation or by installation of properly designed countermeasures (1) ·
Bridge foundations determined to be stable for the assessed or calculated scour condition. Scour is determined to be above top of footing by assessment, by calculation or by installation of properly designed countermeasures (1) ·
Bridge not over waterway. (1)
111908 (1) ·
115378 (1) ·
117980 (1) ·
126655 (1) ·
131860 (1) ·
136198 (1) ·
143138 (1) ·
146608 (1) ·
171592 (1) ·
184778 (1) ·
185298 (1) ·
74196 (1)
Showing below up to 20 results in range #1 to #20.
View (previous 250 | next 250) (20 | 50 | 100 | 250 | 500)