Drilldown: bridge data
From Indian River Lagoon Project
Choose a table:
- Event (169)
- News Link (111)
- Organization (18)
- Waterbody (27)
- bridge (13)
- bridge data (1468)
- definition (254)
- fips (487)
- repository (98)
- timeline (19)
- weblink (123)
Use the filters below to narrow your results.
'Banana River Drive ' (1) ·
'Belcher Canal (C-25) ' (1) ·
'Boynton Canal C16 ' (1) ·
'CANAL L-20 ' (1) ·
'CR-515 & Indian River ' (1) ·
'DRAINAGE DITCH ' (1) ·
'H-20 CANAL ' (1) ·
'OUTFALL CANAL ' (1) ·
'OUTFALL SLOUGH ' (1) ·
'PARK LATERAL CANAL ' (1) ·
'RELIEF CANAL ' (1) ·
'SR-406 ' (1) ·
'Sykes Creek ' (1) ·
'US-1 & FECRR ' (1)
'97 TH STREET ' (1) ·
'AVENUE OF PGA ' (1) ·
'ELLISON WILSON RD ' (1) ·
'HICKORY DRIVE ' (1) ·
'I-95 NB ' (1) ·
'Kings Highway ' (1) ·
'LARCH AVE ' (1) ·
'SR-528 ' (1) ·
'SR-528 WB ' (1) ·
'SR91 N/S TPK 153.7' (1) ·
'SR91 N/S TPK 154.3' (1) ·
'SR91 N/S TPK 156.6' (1) ·
'SR91 NB TPK 158.6 ' (1) ·
'SR91 NB TPK 175.4 ' (1) ·
'SR91 NB TPK 178.03' (1) ·
'SR91 NB TPK 180.16' (1) ·
'SR91 SB TPK 158.6 ' (1) ·
'SR91 SB TPK 175.4 ' (1) ·
'SR91 SB TPK 178.03' (1) ·
'SR91 SB TPK 180.16' (1) ·
'US1(SR5) ' (1)
700014 (1) ·
700015 (1) ·
700025 (1) ·
700026 (1) ·
700134 (1) ·
880057 (1) ·
880058 (1) ·
880059 (1) ·
880065 (1) ·
880066 (1) ·
880067 (1) ·
884003 (1) ·
930001 (1) ·
934131 (1) ·
937005 (1) ·
937006 (1) ·
937007 (1) ·
940007 (1) ·
940058 (1) ·
940064 (1) ·
940065 (1) ·
940083 (1) ·
940110 (1)
'0.1 MI S of PGA BLVD ' (1) ·
'0.1MI W OF MILITARY TRAIL' (1) ·
'0.42 MI NORTH OF SR-68 ' (1) ·
'0.51 MI NORTH OF SR-70 ' (1) ·
'0.7 Mi N of Boynton Bch ' (1) ·
'1.2 MI NORTH OF SR-70 ' (1) ·
'1.3MI N OF PGA BLVD ' (1) ·
'1.5mi. N of SR-68 ' (1) ·
'1.8 MI N OF ST LUCIE CNTY' (1) ·
'13 MI S OF SR 60 ' (1) ·
'13 MI SOUTH OF SR 60 ' (1) ·
'15 MI S OF SR 60 ' (1) ·
'15 MI SOUTH OF SR 60 ' (1) ·
'2.5 MI NORTH OF SR-68 ' (1) ·
'2.53 MI NORTH OF SR-68 ' (1) ·
'2.55 Miles East of SR-3 ' (1) ·
'AT 141st ST ' (1) ·
'I-95 NB over SR-406 ' (1) ·
'SR-528 WB - CR-515 ' (1) ·
'SR-528 WB - Sykes Creek ' (1) ·
'SR-528 WB - US-1 & FECRR ' (1)
26322094 (1) ·
26500997 (1) ·
26501040 (1) ·
26501044 (1) ·
26515320 (1) ·
27250685 (1) ·
27253205 (1) ·
27271813 (1) ·
27281242 (1) ·
27283927 (1) ·
27283929 (1) ·
27333342 (1) ·
27333344 (1) ·
27333350 (1) ·
27333412 (1) ·
27333414 (1) ·
27333415 (1) ·
27461915 (1) ·
28240145 (1) ·
28240489 (1) ·
28241877 (1) ·
28241941 (1) ·
28365910 (1)
80032688 (1) ·
80034800 (1) ·
80062177 (1) ·
80064587 (1) ·
80071574 (1) ·
80235687 (1) ·
80242270 (1) ·
80244387 (1) ·
80254672 (1) ·
80270210 (1) ·
80270308 (1) ·
80365155 (1) ·
80394904 (1) ·
80410794 (1) ·
80410799 (1) ·
80413927 (1) ·
80434234 (1) ·
80434242 (1) ·
80444580 (1) ·
80451074 (1) ·
80454646 (1) ·
80454647 (1) ·
80510378 (1)
Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. (1) ·
Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and brush restrict the channel. (1) ·
Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. (1) ·
N/A (1)
Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. (1) ·
Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting (1) ·
N/A (1) ·
Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. (1)
Bridge foundations determined to be stable for assessed or calculated scour condition. Scour is determined to be within the limits of footing or piles (Example B) by assessment (i.e.,bridge foundations are on rock formations that have been determined to resist scour within the service life of the bridge), by calculations or by installation of properly designed countermeasures (1) ·
Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required to protect exposed foundations (1) ·
Bridge foundations determined to be stable for the assessed or calculated scour condition. Scour is determined to be above top of footing (Example A) by assessment (i.e., bridge foundations are on rock formations that have been determined to resist scour within the service life of the bridge4), by calculation or by installation of properly designed countermeasures (1) ·
Bridge not over waterway. (1)
Showing below up to 23 results in range #1 to #23.
View (previous 250 | next 250) (20 | 50 | 100 | 250 | 500)